FILL 9910
Summary
start: July 17, 2024 11:11:50 AM UTC
end: July 18, 2024 03:21:41 AM UTC
duration: 0 days 16:09:50.272250
tags:
-
PHYSICS
-
WIRES
comments:
-
Strange pattern of emittance in B1 V at injection
-
40% BLM threshold at start of ramp, lifetime >100 h during ramp, and ~20h min lifetime when going into collision
-
Wrong lumi provived by LHCb causing a runaway of levelling until inhibited by 30%/dump on IR8 BLMs
-
SPS switched off TI2/TI8 and clear effect in IP2/8 luminosity
-
7 h of L-levelling
-
Instability in B2 then in B1 following the longitudinal BU (just before switching on the wires)
-
MKB B2 fault induced the dump
Cycle duration

Beta-functions at the IPs

Crossing angles

Octupoles

Trims
Tune trims

Chromaticity Trims

Intensity
Cycle intensity

BBB SB intensity

Violin BBB intensity

SB bunch intensity

Bunch Length

Bunch Length Fill

Emittance
B1 along the cycle

B2 along the cycle

Emittance growth at injection

Summary violin plot

BBB in SB for B1

BBB in SB for B2

Bunch brightness

Beam properties summary

Luminosity
Overview

Luminous Regions

BBB luminosity in SB

Cross-sections
ADJUST




STABLE BEAM