FILL 10650
Summary
start: May 21, 2025 05:49:25 AM UTC
end: May 21, 2025 01:28:38 PM UTC
duration: 0 days 07:39:13.206000
tags:
-
INTENSITY_RAMPUP
-
OP_DUMP
comments:
-
Second fill with 1800b
-
The fill was prematurely OP dumped before loosing teh cryogenic condition of the LHC
-
A sensor on the QURQA P8 is broken. Experts need an access to P8 service area (cryo zone in UX85). The repair will require opening the QURC and take ~3-4 hours. Afterwards, they expect at least 8h for the recovery.
-
During the filling, test with orbit bumps in P4 to check the effect on the BBQ tune measurements. With a -500um bump, a tune shift of 5e-3 was observed. The effect was much smaller for a positive bump.
-
At the start of the ramp, losses at TCLA.D6R7.B1 above 50\% of the dump threshold. The power loss peaked at about 1.5kW.